41
12 Maintenance / Service
y Dry the monitoring bracelet with a cloth after use.
y Charge the battery if the red LED on the monitoring bracelet ashes at one-sec-
ond intervals (when the unit is out of the water). See Charging the monitoring
bracelet’s battery, P. 31.
y Occasionally clean the water contacts on the monitoring bracelet using methyl-
ated spirits.
y Protect the water contacts from soiling (e.g. sun cream).
y Clean the alarm box and cable with a damp cloth. Never use cleaning agents
that contain solvents.
13 Troubleshooting
Problem Possible cause Solution
An alarm is not triggered
during the test with a
monitoring bracelet.
The alarm box is not
connected to the power
supply.
Connect the alarm box to
the power supply.
The monitoring bracelet’s
battery is discharged
(no LEDs illuminate).
See Charging the monitor-
ing bracelet’s battery, P. 31.
The alarm depth set on
the monitoring bracelet is
deeper than the immer-
sion depth.
Verify the monitoring
bracelet settings.
The monitoring bracelet
does not detect water.
Clean the water contacts,
see Maintenance / Service,
P. 41.
The pool sensor is incor-
rectly tted into the
mounting ring.
Ret the pool sensor with
the word "Sensor" facing
into the swimming pool.
During the test the alarm
was not triggered from
all parts of the swimming
pool
The pool sensor cannot
receive the alarm.
Reposition the pool sen-
sor.