Deep Blue BlueFox Basic Instrucciones de operaciones Pagina 16

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 15
16
Procedure
y Connect the 12 V cable to the alarm box and screw tight.
y Fix the 12 V cable.
Danger! Electric shock risk!
Do not use extension cables between the plug-in mains adapter and the
mains socket.
y Insert the plug-in mains adapter into a mains socket (with earth terminal) located
away from the wet area. Use a residual current circuit breaker. (See above, Re-
quirements for the plug-in mains adapter, P. 15). The last selected operating mode
is activated (see Operating principle "passive mode", P. 10, Operating principle "Ac-
tive mode", P. 8, System settings, P. 22.
y If the cable is too short, have an additional mains socket (with residual current
circuit breaker and earth terminal) tted outside the wet area by an approved
electrician.
4.2 Fitting the pool sensor
The pool sensor must be tted to the pool wall 50 cm /1.6 ft beneath the water
surface (PRO 2 pool sensors). It is not necessary to reduce the water depth in order
to t the sensor. The supplied adhesive can be used underwater.
1
Swimming pool
Water surface
50 cm
1.6 ft
Fig. 4 Positioning the pool sensor
y Do not t the pool sensor close to inlet jets, countercurrent systems or air jet
nozzles.
Vista de pagina 15
1 2 ... 11 12 13 14 15 16 17 18 19 20 21 ... 47 48

Comentarios a estos manuales

Sin comentarios